A high-voltage coating is a functional protective and electrical insulation coating for components used in high-voltage systems, particularly in EV batteries and stationary energy storage systems. The focus is not on appearance, but on a technically verifiable protective function.
High-voltage coatings can combine several functions in one coating system:
Typical applications include battery trays, battery enclosures, busbars, battery cooling plates and systems, and ESS modules.
The required function is verified through validated test procedures, such as HiPot testing for electrical insulation as well as corrosion, climate and media resistance testing.
Typical components for high-voltage coating include battery enclosures, battery trays, busbars, battery cooling systems, ESS modules and power electronics components.
The specific coating solution depends on the voltage level, operating environment, component geometry and overall safety concept of the system.
Corrosion protection and electrical insulation serve different protective functions, but in high-voltage applications they must be considered together.
Corrosion resistance is typically verified through project-specific test methods, for example salt spray testing according to DIN EN ISO 9227. Electrical insulation is verified through HiPot testing, high-voltage dielectric testing and, where applicable, insulation resistance measurements.
In high-voltage systems, corrosion can compromise electrical insulation by causing underfilm corrosion, reducing local coating thickness or impairing dielectric properties. BENSELER develops coating systems designed to address both functions in a verifiable way.
In busbars and conductor rails, the surface plays a decisive role in electrical safety and functional performance.
BENSELER supports this through selective coating, defined masking concepts, process-optimized coating thickness distribution and 100% HiPot testing in series production with traceable documentation via DMC code.
The right high-voltage coating for a battery enclosure or battery tray depends on four key factors.
BENSELER combines the suitable coating system with the right pre-treatment, process control and validation strategy.
Recommendation: involve BENSELER as early as possible during component development so that geometry, material and coating can be coordinated before series production approval.
Battery cooling systems and cooling-related components place specific demands on functional coatings.
If high-voltage potentials are present in the surrounding area or relevant insulation distances are affected, the coating system must also meet electrical safety requirements.
BENSELER develops coating solutions that combine thermal, chemical and electrical requirements in one application-specific system.
Electrical insulation performance is verified through a high-voltage dielectric test, commonly referred to as HiPot testing.
The test voltage, dwell time and acceptance limits are defined on a project-specific basis, depending on the component geometry, coating thickness, edges, contact areas, operating voltage level and safety requirements of the overall system.
BENSELER performs HiPot testing in series production and documents the results in a traceable way using DMC codes and a database.
Corrosion resistance is evaluated on a project-specific basis according to customer requirements and recognized test methods.
BENSELER aligns the test strategy with the customer based on media exposure, temperature, humidity, lifetime requirements, safety standards and quality requirements such as IATF 16949 and ISO 9001.
Reproducibility in series production is achieved through a coordinated overall system, not through the coating material alone.
In high-voltage coating, BENSELER validates not only the coating material but the complete system of component, surface, process and test strategy. The result is consistent coating thickness, reliable electrical insulation, reproducible corrosion protection and a safe transition into series production.
Coating as a system solution means that the required function is created by the complete process chain, not by a single coating layer alone.
Optimizing individual process steps in isolation is not enough. Only the interaction of pre-treatment, coating, process control, testing and documentation creates reliable function and reduced series-production risk.
When assembly is safety-relevant, the coating must be designed with assembly requirements in mind from the beginning.
BENSELER addresses this through targeted masking or selective coating, friction-value optimization, in-process control of coating thickness and surface properties, and coordination with the customer regarding assembly parameters and tightening torques.
Fire protection and thermal safety are increasingly important in modern high-voltage systems and battery energy storage systems.
The effect depends on the coating system, material, coating thickness, component geometry, wall thickness and the overall safety strategy. BENSELER evaluates fire protection and thermal safety requirements on a project-specific basis and integrates coatings into broader risk and safety assessments, such as FMEA where applicable.
For a reliable initial assessment of a high-voltage coating, the following information is typically helpful.
Optional but helpful: customer specification, existing coating concepts, target SOP date and information about the prototype or development phase.
With this information, BENSELER can classify the application and prepare an initial technical assessment efficiently.
BENSELER documents HiPot test results systematically and traceably using DMC codes and database-based documentation.
The benefit is 100% test coverage in series production and fast traceability in the event of customer questions, audits or complaints.
Yes. Early involvement is strongly recommended for high-voltage coating projects.
BENSELER supports customers with technical consulting, feasibility assessments based on CAD data or prototypes, sample coating, validation according to customer requirements and project support in line with APQP principles.
Yes. BENSELER supports projects systematically according to established automotive project and quality planning methods, including APQP where required.
For the English website, the headline should use NDA only. The German abbreviation GHV should not be used unless the page specifically addresses German legal terminology.
In general, you will receive feedback within 24 to 48 hours.
For urgent inquiries or ongoing projects, BENSELER can organize short-term technical alignment, either on site or via video conference.
We use cookies to improve your experience with us. These help us to customize content to your interests and provide you with the best possible experience.
Give us the chance to make your experience even better!